Energieffektiviserande åtgärder för befintlig kontorsfastighet på Umestans företagspark : Energy-efficiency measures for existing office building at Umestans Business Park

Detta är en Uppsats för yrkesexamina på avancerad nivå från Umeå universitet/Institutionen för tillämpad fysik och elektronik

Sammanfattning: The work was conducted in the spring of 2016 on behalf of the ÅF Industry in Umeå. This project aimed to provide proposals on energy-saving measures for house 2 at Umestans Business Park based on the total specific purchased energy for 2015. Also for the 3rd floor in the same house suggestions on energy-saving measures were given. This was done with regard to the expected electricity use during 2016. Finally, an investigation on the possibility to classify the floors using of business-electricity was done.Initially was a literature study of today's classification system for buildings done. The focus was to see whether there is a possibility or not to classify leased office space. Both Swedish and international classification systems have been evaluated during the project.All the systems in the building were investigated and the total specific energy could be mapped. All the systems in the building were investigated and the total specific energy could be mapped. Based on the results of the operational-electricity that were emerged during the mapping of house 2, and based on the values of the electricity meter 83353 the business-electricity for floor 3 could be determined. Also for this area a mapping was made to see which areas the business-electricity went to.The results of the mapping of the building showed that the average energy consumption for the total specific purchased energy was 141,1 kWh/m2 per year. Of these districts heating stands for 63%. Of the total share of district heating 81% went to the radiators, this suggests that the building has large transmission losses. The inventory shows that the building's has a low use of electricity. This indicates that the technical systems were well installed with well-adapted operating times. The energy-saving measures that were found to reduce the building's losses were in the areas of windows, ventilation and solar shading. Energy-saving measures for the energy supplied were found in pumps, cooling and lighting.The result of floor 3 shows that the average use of business-electricity is at 36,36 kWh / m2 per year. Of these, 50% goes to lighting.From the results floor 3 could be classified to a Class B using the report "Energy performance of buildings - Energy Classification". To achieve a better classification requires change in the lightning on floor 3 as well as an analysis of any thinkable behavior change among the employees.

  HÄR KAN DU HÄMTA UPPSATSEN I FULLTEXT. (följ länken till nästa sida)