Fukttillstånd i betongplatta på mark : Ett experimentellt försök att jämföra teori med praktik

Detta är en M1-uppsats från Högskolan i Gävle/Avdelningen för bygg- energi- och miljöteknik

Sammanfattning: When casting the slab in a slab-on-ground structure most of the drying will occur through the surface of the slab, which is in contact with the air. This will create a non-uniform internal moisture distribution. With the top of the slab drying faster it will also have a faster shrinkage due to drying, which in turn leads to stress in the surface layers of the slab as these wants to contract. With the slab wanting to assume a curled geometry, but being restricted by external loads and self-weight, cracks will usually appear in the surface (Lange, Lee & Liu, 2011).  A concrete slab-on-ground does not dehydrate the same way as, for example, floor bellows or wall elements which has the same climate on both sides. The ground beneath a heated building standing on a slab-on-ground structure is warm and moist with a relative moisture close to 100%. After carefully examining moisture damaged slab-on-ground structures it was concluded that the temperature and moisture behavior in this type of structure is more complicated than earlier presumed. In an attempt to broaden the basis of knowledge about humidity conditions under a concrete slab-on-ground structure, measurements were performed on an existing slab.  The Council for Construction Competence (Rådet för ByggKompetens, RBK) sets the industry standard regarding moisture measurement in Sweden. In 2017 the method recommended by RBK for moisture measurement in concrete includes drilling a hole in the slab, sealing it with a plastic pipe and mounting the sensor inside. This is the method that was used for measurements in this paper. Three different measurement locations in the slab along with two sensors mounted at every location was used to gather data.  The results from the measurements show that the relative humidity near the bottom of the slab is close to 100%. The results from the sensors range from 90% to 100% RH with the majority of the results very close to 100% RH. The results discovered in this paper supports the assumption that the ground beneath a slab-on-ground structure is close to 100% RH.

  HÄR KAN DU HÄMTA UPPSATSEN I FULLTEXT. (följ länken till nästa sida)