Sökning: "DFIG"

Visar resultat 1 - 5 av 14 uppsatser innehållade ordet DFIG.

  1. 1. Fault current injection from Inverter Based Generation in the distribution grid : A case study of distribution grid on the Swedish island of Gotland

    Master-uppsats, Uppsala universitet/Institutionen för elektroteknik

    Författare :Farsad Mansori; [2022]
    Nyckelord :Distribution generator; Inverter-Based Distributed Generation; Inverter Based Generation; DFIG; PSCAD; Distribution grid; Overcurrent protection;

    Sammanfattning : This work proposes recommendations for new guidelines for fault current injection on a distribution grid. These guidelines will help improve the transition towards renewable electrical energy generation. LÄS MER

  2. 2. Application of harmonic injection method to analyse Sub-Synchronous Control Interactions (SSCI)

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Linus Eriksson; [2022]
    Nyckelord :Sub-synchronous control interaction SSCI ; damping of SSCI; DFIG; PSCAD; Power Oscillation Damper POD ; Harmonic Injection; Subsynkrona kontrollinteraktioner SSCI ; dämpning av SSCI; DFIG; PSCAD; Dämptillsats POD ; Harmonisk Injection;

    Sammanfattning : Wind farms are commonly connected to the main grid through compensated lines which increases the power transfer capability of the line. Double Fed Induction Generator (DFIG) wind turbines in connection to compensated lines can experience Sub-Synchronous Control Interaction (SSCI) which can bring system quantities above allowed levels. LÄS MER

  3. 3. Damping of sub-synchronous control interactions with a STATCOM : Wind farms & series compensated power lines

    Master-uppsats, Uppsala universitet/Institutionen för elektroteknik

    Författare :Leonardo Alvarez Urrutia; [2022]
    Nyckelord :Sub-Synchronous Control Interactions; Power Systems; STATCOM; Network Stability; Doubly-Fed Induction Generator; Impedance-Based Stability Analysis;

    Sammanfattning : The power converter is one of the key components in power system applications such as high voltage direct current (HVDC) systems and the grid connection of intermittent sources such as wind and solar power. However, the increased penetration of converter-based generation introduces challenges, such as sub-synchronous interaction between the converter control system and the grid. LÄS MER

  4. 4. Mitigating SSCI in a hybrid wind and PV farm utilizing PV-STATCOM : A Swedish case study

    Master-uppsats, Högskolan Dalarna/Institutionen för information och teknik

    Författare :Isabelle Löfgren; [2022]
    Nyckelord :impedance analysis; PV-STATCOM; SSCI; SSO; SSR; sub-synchronous control interaction;

    Sammanfattning : The share of electricity generation in the power system being based on power electronics is increasing, which will impact the system in different ways, such as an increased risk for undesired interactions. An example is doubly fed induction generator (DFIG) based windfarms which have been shown to present negative resistance in (parts of) the sub-synchronous range (i. LÄS MER

  5. 5. The Impact of Voltage Dip Characteristics on Low Voltage Ride Through of DFIG-based Wind Turbines

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Cheng Chen; [2019]
    Nyckelord :DFIG; wind power; low voltage ride through; power quality; voltage dip;

    Sammanfattning : In last decade, there is a large increase in installed capacity of wind power. Asmore wind power is integrated into utility networks, related technologychallenges draw much attention. The doubly fed induction generator (DFIG) isthe mainstream choice for wind turbine generator (WTG) in current market andthe object of this thesis. LÄS MER