Sökning: "EBCT"

Visar resultat 1 - 5 av 9 uppsatser innehållade ordet EBCT.

  1. 1. Is two stage GAC better than one stage GAC for removing PFAS at a DWTP? : Investigation of PFAS removal from drinking water using two stage granular activated carbon (GAC) filter

    Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Institutionen för geovetenskaper

    Författare :Oliver Ekesiöö; [2023]
    Nyckelord :GAC; PFAS; drinking water treatment; two stage GAC;

    Sammanfattning : The removal of 34 per- and polyfluoroalkyl substances (PFAS) were compared in a 1 stagegranular activated carbon (GAC) filtration to a 2 stage GAC filtration in a pilot study at adrinking water treatment plant (DWTP). The PFASs that were present in the water wereperfluorooctanoic acid (PFOA), perfluorooctane sulfonic acid (PFOS), perfluoropentanoic acid(PFPeA), perfluorohexanoic acid (PFHxA), perfluoroheptanoic acid (PFHpA), perfluorobutanesulfonic acid (PFBS), perfluoropentane sulfonic acid (PFPeS) and perfluorohexane sulfonic acid(PFHxS). LÄS MER

  2. 2. Utvärdering av långtidstester med aktivt kol och anjonbytare för avskiljning av läkemedelsrester och PFAS från kommunalt avloppsvatten : Reningseffektivitet, kostnad och klimatpåverkan

    Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Institutionen för geovetenskaper

    Författare :Sofia Olsson; [2023]
    Nyckelord :Pharmaceuticals; PFAS; PFOS; Activated Carbon; Anion Exchange; Advanced Treatment; Wastewater Treatment Plant; Cost; Climate Impact; Läkemedel; PFAS; PFOS; Aktivt kol; Anjonbytare; Avancerad rening; Avloppsreningsverk; Kostnad; Klimatpåverkan;

    Sammanfattning : Avloppsreningsverk utgör en viktig spridningsväg för läkemedelsrester till den akvatiska miljön. Även per- och polyfluorerade alkylsubstanser (PFAS) har påvisats i utgående vatten från avloppsreningsverk. För att minska utsläpp av dessa krävs ett kompletterande reningssteg. LÄS MER

  3. 3. Evaluation of two-stage GAC filtration for PFAS reduction in drinking water

    Master-uppsats, SLU/Department of Molecular Sciences

    Författare :Julia Söderberg; [2023]
    Nyckelord :Per- and polyfluoroalkyl substances PFAS ; Granular activated carbon GAC ; drinking water; removal efficiency; DWTP;

    Sammanfattning : PFAS, or per- and polyfluoroalkyl substances, are a group of chemicals found in a wide range of industrial and consumer products. Due to their persistent nature and widespread use, concerns have been raised about their impact on human health and the environment. LÄS MER

  4. 4. GAC filter Design Criteria for Wastewater Treatment for Removal of Organic Micropollutants – A Literature Review

    Master-uppsats, Lunds universitet/Kemiteknik (CI)

    Författare :Bhargav Reddy Elavarthi; [2021]
    Nyckelord :micropollutants; activated carbon filtration; empty bed contact time EBCT ; pharmaceuticals; breakthrough curves; adsorption; PFOS; carbon use; water and environmental engineering; Technology and Engineering;

    Sammanfattning : Granular Activated Carbon (GAC) is nowadays suggested as a fourth (quaternary) treatment step at municipal wastewater treatment plants to remove certain chemicals and particularly organic micropollutants (OMPs). This work investigated the different factors that affect the performance of the GAC filter for the removal of micropollutants in a municipal wastewater treatment plant. LÄS MER

  5. 5. Utvärdering av effektivitet för aktivt kol och anjonbytare vid reduktion av per- och polyfluorerade alkylsubstanser (PFAS) samt läkemedelssubstanser i avloppsvatten

    Master-uppsats, Uppsala universitet/Institutionen för geovetenskaper

    Författare :Monika Kalecinska; [2021]
    Nyckelord :PFAS; pharmaceuticals; wastewater treatment plant; advanced treatment; activated carbon; anion exchange; PFAS; läkemedel; avloppsreningsverk; avancerad rening; aktivt kol; anjonbytare;

    Sammanfattning : Avloppsreningsverk (ARV) utgör en viktig del som spridningsväg för utsläpp av organiska mikroföroreningar, som per- och polyfluorerade alkylsubstanser (PFAS) och läkemedelssubstanser, från samhället till den akvatiska miljön. Befintliga reningssteg vid ARV reducerar mikroföroreningar dåligt varav denna studie syftade till att jämföra reduktionseffektiviteten av 5 olika granulära aktiva kol (GAK) och en anjonbytare (AIX) för att välja ut det material som är mest lämpat för vidare undersökningar i pilotskala inför installation ett avancerat reningssteg i Kungsängsverkets ARV i Uppsala. LÄS MER