11. Statistical analysis of firefighting and damage caused by fire in mid-rise timber-framed residential buildings compared to other construction types
Master-uppsats, Lunds universitet/Avdelningen för BrandteknikSammanfattning : The contribution of greenhouse gas emissions in the production of construction materials has sparked a new interest and recent changes in building regulations regarding the use of renewables like wood as the main component in load-bearing elements. Recent regulation changes focus on allowing taller timber structures which bides the question of how to adequately maintain an acceptable level of fire protection considering the characteristically flammable properties of wood-based products. LÄS MER
12. The Kiruna town move : Unearthing the possibilities for full-scale fire tests
Uppsats för yrkesexamina på grundnivå, Luleå tekniska universitet/Byggkonstruktion och brandSammanfattning : The work with this thesis started during the last semester at the Fire Protection Engineering program at Luleå University of Technology. Kiruna has relied on the iron ore resources of Luossavaara and Kiirunavaara since the creation of the town. The iron ore stretches underneath the current city center. LÄS MER
13. Test av brandskyddslösning på radhusvindar med innertak av råspont
Uppsats för yrkesexamina på grundnivå, Luleå tekniska universitet/Institutionen för samhällsbyggnad och naturresurserSammanfattning : Bränder i radhus har under en längre tid varit förödande, oftast med hela radhuslängor totalförstörda. Branden sprider sig upp till vinden för att normalt mötas av en bristande avskiljande vägg. LÄS MER
14. Brandteknisk dimensionering av limträkonstruktioner : En jämförelse mellan förenklad och analytisk dimensionering med avseende på materialåtgång
Uppsats för yrkesexamina på grundnivå, Uppsala universitet/Tillämpad mekanikSammanfattning : This thesis examines the possibility of saving material by using analytical design of fire protection of glued laminated timber structures instead of the standard simplified design approach. The thesis is based on an existing store building (building class Br2 and occupancy class 2B) where Tyréns AB has determined a fire exposure specific for the store building, which is used to simulate 30 minutes of fire. LÄS MER
15. Performance of joints for glued laminated timber exposed to the ISO fire temperature curve
Master-uppsats, Lunds universitet/Avdelningen för BrandteknikSammanfattning : As society becomes more ecologically conscious there is a push toward the use of materials with a smaller environmental burden, one of these materials is glulam (GLT), which has gained a lot of traction in recent years not only for ecological reasons but for its ease in manufacture, transport, noise dampening, etc. The focus of this project was to evaluate the influence of different joint configurations on the fire performance of glulam members. LÄS MER