Sökning: "distansskydd"

Visar resultat 1 - 5 av 7 uppsatser innehållade ordet distansskydd.

  1. 1. Line Distance Protection in Power Grids with Variable Renewable Energy Sources : An Investigation on Time Domain Distance Protection via Parameter Estimation

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Ludvig Ringaby; [2023]
    Nyckelord :Distance protection; Power system protection; Time domain distance protection; Differential Equation Algorithm; Variable renewable energy; IBR; Distansskydd; Skyddssystem i elkraftsystem; Tidsdomän distansskydd; Differentialekvationsalgoritm; Variabel förnybar energi;

    Sammanfattning : Variable renewable energy sources typically connect to the power grid through power electronic interfaces. Increased use of such sources can cause issues for conventional distance protection. LÄS MER

  2. 2. Fördjupning i impedansskyddets funktion, nätets påverkande faktorer samt utvärdering av provningsrutin

    Kandidat-uppsats, Högskolan Väst/Institutionen för ingenjörsvetenskap

    Författare :Michelle Petersson; [2023]
    Nyckelord :impedansskydd; provningsrutiner;

    Sammanfattning : Kraftsystemet består av flera olika komponenter som är nödvändiga för ett fungerande elnät.Både ur ett leveranssäkert- och personsäkert perspektiv är det nödvändigt med ett skyddssystem som kan frånkoppla anläggningsdelar vid fel. LÄS MER

  3. 3. Implementation Av Reläskyddssamverkan : En studie om en effektiv reläskyddssamverkan med hjälp av längsdifferentialskyddets kommunikationskanaler

    Kandidat-uppsats, KTH/Hälsoinformatik och logistik

    Författare :Khalid Husen; Fadi Imad Mousa; [2021]
    Nyckelord :Teleprotection scheme; distance protection; earth fault protection; protective relays.; Reläskyddssamverkan; reläskydd; teleskyddsschema; distansskydd; jordfelsskydd;

    Sammanfattning : En tranmissionsledning är delen av elsystemet som överför ström från kraftverk till slutanvändare. Därför är det av vikt att en transmissionslinje alltid ska vara skyddad. LÄS MER

  4. 4. Cross-Country Faults in Resonant-Earthed Networks

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Gabriel Miguel Gomes Guerreiro; [2020]
    Nyckelord :Cross- country fault; resonant earthing; compensated network; MV network; distance protection; fault analysis; RTDS EMTDC.; dubbla jordfel; spoljordning; jordfelskompenserade elnät; mellanspänningsnät; distansskydd; reläskydd; RTDS EMTDC.;

    Sammanfattning : Reliability requirements for power systems have been constantly increasing, as customers of electric power desire high power availability. In order to improve continuity of supply in medium voltage (MV) networks, utilities in many countries in Europe, North/South America and Oceania use resonant earthing and allow the operation of the network during a single phasetoearth fault for periods from several seconds up to several hours, since the earthfault current at the fault point in such systems is considerably reduced and is unlikely to damage equipment or create hazardous voltages for people or livestock. LÄS MER

  5. 5. The impacts of series compensated EHV lines on distance protection, and a proposed new mitigation solution

    Master-uppsats, KTH/Elektroteknisk teori och konstruktion

    Författare :Syed Arif Ullah Shah; [2017]
    Nyckelord :Series compensation; metal oxide varistor; voltage inversion; current inversion; sub-synchronous oscillation; quadrilateral characteristic distance relay; digital high-pass filter; Seriekompensation; metalloxidvaristor; spänningsinversion; ströminversion; subsynkron oscillation; fyrsidig karakteristiskt distansrelä; digitalt högpassfilter;

    Sammanfattning : Series compensation is extensively applied to the transmission lines to increase the power transfer capability of transmission lines, reduce transmission losses, improve voltage profiles, and improve power oscillation damping and transient stability of power systems. But it modifies the apparent impedance of the transmission lines during fault conditions and might cause the distance protection of transmission lines to encounter directional discrimination issues and reach problems. LÄS MER