Sökning: "isocenter"
Visar resultat 1 - 5 av 17 uppsatser innehållade ordet isocenter.
1. osimetric impact of system spe cific geometric distortion on head and neck treatment plans in MRI only based radiation therapy
Master-uppsats,Sammanfattning : Background/ purpose: Because of the superior soft tissue contrast, in comparison with computed tomography (CT) data, magnetic resonance imaging (MRI) is of high interest to include in a larger extent in the ra diation therapy (RT) process. In an MRI only workflow, the CT scan is excluded and a synthetic CT is used for treatment plan ning. LÄS MER
2. Deep reinforcement learning for isocenter placement in Gamma Knife® radiosurgery
Master-uppsats, Uppsala universitet/Institutionen för informationsteknologiSammanfattning : Disposition of isocenters inside the brain tumor is of paramount importance for the quality of the Leksell Gamma Knife® radiosurgery. This work presents a novel approach based on deep reinforcement learning aimed at optimizing isocenter locations. LÄS MER
3. Automation of robust Pareto front-based radiotherapy treatment planning for prostate cancer patients
Master-uppsats, Lunds universitet/SjukhusfysikerutbildningenSammanfattning : Purpose/objective The main objective was to create a software that automates the process of creating treatment plans used for Pareto front-based dose planning for prostate cancer patients. A second objective/purpose was to add a robustness test to this program to evaluate the effect of prostate movements on the treatment plans. LÄS MER
4. Validation of Catalyst HD™ positioning performance using a deformable phantom
Master-uppsats, Lunds universitet/SjukhusfysikerutbildningenSammanfattning : Aim: The overall purpose for this master thesis was to evaluate the deformable algorithm of the optical surface scanning system Catalyst HDTM . The aim was to develop a method to evaluate the non-rigid registration algorithm using a deformable phantom and with it investigate the positioning accuracy of the depth calculation. LÄS MER
5. Surface guided radiotherapy for high precision treatments of brain metastases
Master-uppsats, Lunds universitet/SjukhusfysikerutbildningenSammanfattning : Purpose/Background High accuracy treatment techniques such as stereotactic radiotherapy (SRT) requires precise patient positioning prior to and during treatment. The Catalyst™ is an optical surface scanning (OSS) system that has been utilized for patient positioning and real time monitoring during radiotherapy. LÄS MER