Brandteknisk Riskvärdering Sveaplan Köpcentrum

Detta är en L3-uppsats från Lunds universitet/Avdelningen för Brandteknik; Lunds universitet/Avdelningen för Riskhantering och Samhällssäkerhet

Sammanfattning: Abstract The main purpose of the report is to examine the egress safety at Sveaplan köpcentrum in Eskilstuna in case of fire. Sveaplan köpcentrum is a shopping mall with different kinds of shops and a restaurant. When visiting the shopping centre two of the compartments were empty and two fictitious companies were therefore pursued. Three different fire scenarios were analyzed and simulated in the programs FDS and Simulex. The total evacuation time was compared with the time for critical conditions to develop, to see if the requirements were fulfilled or not. The conclusion for Sveaplan köpcentrum is that they have a good egress safety in case of fire but that some minor measurement should be done to secure the safety. Following measurement shall be done • Objects that block the emergency exits shall be removed. • Optical alarms shall be installed in restrooms • Emergency exits where people with disabilities can evacuate shall be well marked. • Installation of fire safe glass in the opening between the two decks and installation of fire smoke vents. • Remove the shopping carts. • Installation of more smoke detectors at the upper floor. • At the places where egress signs are missing or insufficient shall complement be done.