Sökning: "Detector Physics"
Visar resultat 1 - 5 av 203 uppsatser innehållade orden Detector Physics.
1. Misalignment effects on the physics performance of the inner tracker upgrade at the ALICE experiment
Master-uppsats, Lunds universitet/Fysiska institutionen; Lunds universitet/Partikel- och kärnfysikSammanfattning : This thesis deals with the physics performance of an approved inner tracker upgrade of the ALICE experiment involving a novel and ultra-thin silicon detector with a cylindrical geometry. During the thesis work, a method was developed in simulations to induce distortions to the detector’s geometry, and the resulting loss in physics performance was evaluated. LÄS MER
2. Simulation-based discrimination of Crab pulsar models with XL-Calibur
Master-uppsats, KTH/FysikSammanfattning : Polarisation of X-ray light is being investigated with polarimeters to extend the borders of what can be observed. Distant compact objects, such as pulsars, that are to small on the sky to be analysed with imaging can be investigated by analysing the polarisation of the emitted light. This can reveal physics previously hidden by their small nature. LÄS MER
3. Structural analysis of HZO thin film and electrode using X-ray diffraction
Kandidat-uppsats, Lunds universitet/Synkrotronljusfysik; Lunds universitet/Fysiska institutionenSammanfattning : Since its discovery in 2011, the ferroelectricity of thin films based on HfO2 has been studied intensively. In particular, thin films with a 1:1 ratio of HfO2 and ZrO2 (HZO) has been of great interest. The ferroelectricity arises from a non-centrosymmetric orthorhombic (o) phase of HZO whose prevalence is dependent on the processing conditions. LÄS MER
4. Non-linear effects in the ATLAS track-counting luminosity measurement
Master-uppsats, Uppsala universitet/HögenergifysikSammanfattning : In this thesis the linearity of the ATLAS track-counting luminosity measurement is studied using two different sets Monte Carlo simulated crossings of proton-proton bunches. A primary high-momentum, or hard, interaction must be chosen for the Monte Carlo simulation. LÄS MER
5. Quality enhancement of time-resolved computed tomography scans with cycleGAN
Master-uppsats, Lunds universitet/Synkrotronljusfysik; Lunds universitet/Fysiska institutionenSammanfattning : Time-resolved x-ray tomography enables us to dynamically and non-destructively study the interior of a specimen. The obtainable temporal resolution is limited by the x-ray flux and the desired spatial resolution. LÄS MER