Sökning: "ordered Subset Expectation Maximization"

Hittade 5 uppsatser innehållade orden ordered Subset Expectation Maximization.

  1. 1. Effects of reconstruction parameters on the image quality and quantification of PET images from PET/MRI and PET/CT systems

    Master-uppsats,

    Författare :Ali Amena Hussain; [2022-03-09]
    Nyckelord :Medical physics; PET CT; PET MRI; OSEM; BPL; NEMA IQ; positron emission tomography; magnetic resonance imaging; computed tomography; ordered Subset Expectation Maximization; The Bayesian Penalized Likelihood;

    Sammanfattning : Aim: To study how reconstruction parameters affect the positron emission tomography (PET) image quality and quantitative results for the different lesion to background radioactivity ratios in three different PET systems. Introduction: Multimodality imaging that combines magnetic resonance imaging (MRI) or computed tomography (CT) with a PET system can produce medical images containing both functional and anatomical information. LÄS MER

  2. 2. Rekonstruktionens påverkan av kvantitativ bedömning vid FET-PET

    Kandidat-uppsats, Malmö universitet/Fakulteten för hälsa och samhälle (HS)

    Författare :Hava Taipova; [2020]
    Nyckelord :FET-PET; gliom; SUV; TBR; tumör;

    Sammanfattning : Flour-etyl-L-tyrosin positronemissionstomografi (FET-PET) undersökning är en undersökningsmetod som har hög sensitivitet och specificitet vid diagnostisering av bland annat tumör och tumörrecidiv. För att bestämma FET-upptaget i tumören kan tumör till bakgrundsförhållande (TBR) beräknas. LÄS MER

  3. 3. Volume calculation of the thyroid gland from SPECT images based on Monte Carlo simulations

    Uppsats för yrkesexamina på avancerad nivå, Umeå universitet/Radiofysik; Umeå universitet/Institutionen för fysik

    Författare :Niklas Palmqvist; [2018]
    Nyckelord :nuclear medicine xeleris thyroid hyperthyroidism thyrotoxicosis monte carlo technetium iodine;

    Sammanfattning : In this study the volume determination which is a part of the doseplanning for patients with thyrotoxicosis was investigated. The aim was to find an accurate method to determine the active volume with single photon emission tomography (SPECT) which in several studies have shown better results than with the currently used method planar scintigraphy (PS). LÄS MER

  4. 4. Optimering av bildkvaliteten för SPECT-undersökningar med 111In-Octreoscan vid Norrlands universitetssjukhus : -en Monte Carlo studie

    Master-uppsats, Institutionen för strålningsvetenskaper; Institutionen för fysik

    Författare :Emma Mähler; [2011]
    Nyckelord :SPECT; gammakamera; Octreoscan; bildkvalitet; OSEM-iteration; kontrast;

    Sammanfattning : Inom nuklearmedicinsk diagnostik används radioaktiva läkemedel för att utvärdera olika organs metabolism och fysiologiska beteende. Genom att använda en scintillationskamera kan strålningen som erhålls när det administrerade läkemedlet sönderfaller i kroppen detekteras och en funktionell bild över aktivitetsfördelningen erhålls. LÄS MER

  5. 5. Characterization and Reduction of Noise in PET Data Using MVW-PCA

    Master-uppsats, Institutionen för informationsteknologi

    Författare :Per-Edvin Svensson; [2009]
    Nyckelord :;

    Sammanfattning : Masked Volume-Wise Principal Component Analysis (MVW-PCA) is used in Positron Emission Tomography (PET) to distinguish structures with different kinetic behaviours of an administered tracer. In the article where MVW-PCA was introduced, a noise pre-normalization was suggested due to temporal and spatial variations of the noise between slices. LÄS MER