Åtgärdsförslag och känslighetsanalys vid energieffektivisering ur ett fuktsäkert perspektiv : En fallstudie på timmerhuset Sofiedals herrgård

Detta är en M1-uppsats från Högskolan i Gävle/Avdelningen för bygg- energi- och miljöteknik

Sammanfattning: This thesis investigated the possibilities to resume cultivation of an old manor house built of timber and what this would mean from an energy and moisture perspective. The building in this case study is named Sofiedals mansion and was built in 1858 in Valbo 11 kilometers west of Gävle. The structure of the house was documented and used as a starting-point for carrying out calculations focused on energy and moisture aspects. With the help of a number of computer programs and a conducted air tightness test, the buildings energy consumption were calculated and compared with the current building regulations. In addition, the building was analyzed considering energy retrofitting and what it meant for moisture problems. The energy retrofitting consisted of additional insulation, decreasing the buildings permeability through air sealing; window and door replacements. When a building is equipped with natural ventilation it is difficult to know its precise performance and how an energy retrofitting affects it. Therefore a sensitivity-analysis was performed on four different types of ventilation performance and how they affected the buildings energy as well as its building components moisture performance. The proposed suggestion for an energy retrofitting was made with a potential buyer in mind. Therefore general problems have been documented to demonstrate other measures to be taken into consideration when cultivating the building. The investigation showed that the buildings energy consumption needs to be reduced by approximately 45% to achieve the goal of Swedens current building regulations. Depending on the presumed ventilation performance, the energy consumption and moisture content in the building components varied. The conducted sensitivity analysis showed that a vapour barrier is required to make the building safe from moisture problems. In order to achieve the building regulations energy demands a specific energy consumption of 110kWh/m 2 each year was required. Currently the building does not meet these requirements and needs to undergo an extensive retrofitting.

  HÄR KAN DU HÄMTA UPPSATSEN I FULLTEXT. (följ länken till nästa sida)