Sökning: "acrylamide"
Visar resultat 1 - 5 av 18 uppsatser innehållade ordet acrylamide.
1. Polymer gel dosimetry with MRI-readout for 3D dose verification - detector characteristics and clinical applications
Master-uppsats, Lunds universitet/SjukhusfysikerutbildningenSammanfattning : Background & Purpose: Radiation therapy is an essential treatment for cancer patients with the ultimate goal to deliver radiation doses to the tumour with precision while minimizing exposure to surrounding healthy tissues. Treatment verification is crucial to ensure the accuracy of radiation delivery, for instance by measuring the radiation dose distribution. LÄS MER
2. Reduction of Acrylamide in Reject Water from Sludge Dewatering
Master-uppsats, KTH/Hållbar utveckling, miljövetenskap och teknikSammanfattning : Norrvatten produces and delivers drinking water to approximately 700 000 people in the northern part of the Stockholm region in Sweden. In their water treatment plant Görvälnverket, water from Lake Mälaren is purified. During the purification, sludge is produced. To be able to use the sludge as landfilling material, it must be dewatered. LÄS MER
3. CHARACTERIZATION AND EVALUATION OF A NIPAM POLYMER GEL MRI DOSIMETER SYSTEM
Master-uppsats,Sammanfattning : Purpose: The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. However, limited work have been done in vestigating this dosimeter. The dose response and reproducibility of a NiPAM dosimeter was investigated. LÄS MER
4. Hyaluronic Acid Hydrogel as a Scaffold for Cells’ Encapsulation
Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Institutionen för materialvetenskapSammanfattning : Hydrogels are high water-content polymers that mimic the extracellular matrix of cells. The polymers can have many sources and be of natural origin from the extracellular matrix (ECM) of cells or be synthetically derived. LÄS MER
5. Polymer gel dosimetry - Using MRI-readout, simplified relatively non-toxic mixing procedure tested on FLASH
Master-uppsats, Lunds universitet/SjukhusfysikerutbildningenSammanfattning : Background: One of the polymer gel dosimeters available today is the N-isopropylamide (NIPAM) polymer gel dosimeter which has a less toxic monomer compared to other polymer gels and the advantage of being able to be manufactured under normal oxygen levels. Polymer gel dosimeters in general are advantageous independent dosimeters to use for verification of new radiation treatment techniques due to its favorable qualities such as very high resolution, 3D coverage, tissue equivalence and independence of energy and incident direction of the radiation beam. LÄS MER