Sökning: "Phase contrast MRI"
Visar resultat 1 - 5 av 24 uppsatser innehållade orden Phase contrast MRI.
1. Phase Unwrapping MRI Flow Measurements
Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Avdelningen Vi3Sammanfattning : Magnetic resonance images (MRI) are acquired by sampling the current of induced electromotiveforce (EMF). EMF is induced due to flux of the net magnetic field from coherent nuclear spins with intrinsic magnetic dipole moments. LÄS MER
2. Development of a tool for analysis and visualization of longitudinal magnetic resonance flowmeasurements : of subarachnoid hemorrhage patients in the neurointensivecare unit
Master-uppsats, Linköpings universitet/Institutionen för medicinsk teknikSammanfattning : Patients who are treated in an intensive care unit need continuous monitoring in orderfor clinicians to be prepared to intervene should a secondary event occur. For patientstreated at the neurointensive care unit (NICU) who have suffered a subarachnoid hemorrhage (SAH) this secondary event could be ischemia, resulting in a lack of blood flow. LÄS MER
3. Designing k-Space Filters to Improve Spatiotemporal Resolution with Sector-Wise Golden Angle (SWIG)
Master-uppsats, KTH/Medicinteknik och hälsosystemSammanfattning : The aim of this thesis is to design and evaluate k-space weighting filters for simultaneously improving the spatial and temporal resolution of cardiovascular MRI, with the ultimate goal of improving the accuracy of quantitative flow measurements, which are important for diagnosis and follow-up of heart dysfunction. Two different k-space filters were implemented and evaluated retrospectively to already acquired data. LÄS MER
4. Functional connectivity analysis in the human brain using ultra-high field MRI
Master-uppsats, Lunds universitet/Examensarbeten i bioinformatikSammanfattning : Introduction: Functional magnetic resonance imaging (MRI) is a non-invasive method which uses a combination of a strong magnetic field and radio frequency pulses to image magnetic difference between oxygenated and deoxygenated blood in the human brain. This contrast differences can be used to identify areas in the brain when subjects performing an active task in the MRI scanner. LÄS MER
5. Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
Master-uppsats, KTH/Skolan för kemi, bioteknologi och hälsa (CBH)Sammanfattning : Doppler echocardiography is the conventional method for measurement of myocardial motion. However, the same clinical parameters can be measured with phase contrast magnetic resonance imaging (MRI). LÄS MER