1. Towards a Data-Driven Approach to Ground-Fault Location in Distribution Power System using Artificial Neural Network
Master-uppsats, Linnéuniversitetet/Institutionen för fysik och elektroteknik (IFE)Sammanfattning : Motivated by the need for less polluting energy production, the recent increase in renewable electricity production is reshaping classical power systems. Initially unidirectional and constant power flow becomes multi-directional and dynamic. As one of the many consequences, classical power system fault location methods might become outdated. LÄS MER
2. IT-kopplade AC-nät : Enpoliga jordfel i befintlig elanläggning under jord
Uppsats för yrkesexamina på grundnivå, Umeå universitet/Institutionen för tillämpad fysik och elektronikSammanfattning : In some electrical facilities for underground mining, IT-system grounding is used for processes of high priority. This report explains why such systems are used in these kinds of environments, what happens when single-line-ground faults occur and how does the fault protection and monitoring devices handle those faults in accordance to current regulations and standards. LÄS MER
3. Användande av lokala nollpunktsreaktorer : Hantering av kapacitiva jordfelsströmmar i kabelnät
M1-uppsats, Umeå universitet/Institutionen för tillämpad fysik och elektronikSammanfattning : The rural power grid has traditionally mostly consisted of overhead power lines. In recent years the trend has been to replace the overhead lines with cables instead. The reason is that overhead lines are relatively vulnerable, strong winds and storms can cause trees and branches to fall over the power lines and cause a phase to ground fault. LÄS MER
4. Grounding of distrubution grids : High impedancegrounding compared to solid grounding with Fault Current Limiter
Uppsats för yrkesexamina på avancerad nivå,Sammanfattning : Today cables replace overhead lines in distribution systems and cause higher system capacitance and higher capacative fault currents. This fault current, in the fault location, is limited by a Petersén coil and a resistance in parallel when a fault occurs in so called “high impedance grounded systems” which are commonly used in Europe. LÄS MER
5. Tillståndsbedömning av kablar i mellanspänningsnät : En sammanställning av olika metoder för kabeldiagnostiska mätningar och tester
Uppsats för yrkesexamina på grundnivå, Luleå tekniska universitet/Institutionen för teknikvetenskap och matematikSammanfattning : Detta examensarbete utfördes vid Bodens Energi Nät AB under våren 2017 och behandlar mätmetoder och olika tester som kan utföras på markförlagd kabel för kontroll av tillståndet på exempelvis isolation, mantel och skarvar. Bakgrunden till arbetet är att man inom Bodens Energi Nät har ett flertal kilometer kabel på mellanspänningsnivå 20 kV. LÄS MER