Sökning: "Electroencephalography device"
Visar resultat 1 - 5 av 7 uppsatser innehållade orden Electroencephalography device.
1. Developing a portable, customizable, single-channel EEG device for homecare and validating it against a commercial EEG device
Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)Sammanfattning : There are several commercial electroencephalography (EEG) devices on the market; however, affordable devices are not versatile for diverse research applications. The purpose of this project was to investigate how to develop a low-cost, portable, single-channel EEG system for a research institute that could be used for neurofeedback-related applications in homecare. LÄS MER
2. Integration of Bluetooth Sensors in a Windows-Based Research Platform
Kandidat-uppsats, Malmö universitet/Institutionen för datavetenskap och medieteknik (DVMT)Sammanfattning : This thesis describes how to build a solution for transmitting data from an Electroencephalography (EEG) device to a server in real-time while guiding the user through a number of predefined exercises. This solution will be used by Spinal Cord Injury (SCI) patients suffering from neuropathic pain, in order to understand if it is possible to predict such pain from EEG. LÄS MER
3. Development of an Intelligent Embedded Interface for Interpreting Biosignals Recorded by Novel Wearable Devices
Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)Sammanfattning : In recent years there has been a considerable development in the realm of sensing technologies, embedded systems, wireless communication technologies, nanotechnologies, and miniaturization has made it possible to create smart wearable systems that can record data from the human bodies and monitor our daily activities. Most expectations for the successful deployment of wearable devices and their tangible impact for the society is in healthcare. LÄS MER
4. Preamplifier Design for Active Electrodes in Single-Channel EEG Applications
Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)Sammanfattning : The implementation of portable electroencephalography (EEG) systems has been known to be complex. During ambulation, the integrity of recorded EEG signals is often impaired by motion artifacts and the time and effort required to set up the system is excessive. LÄS MER
5. OAP: An efficient online principal component analysis algorithm for streaming EEG data
Master-uppsats, Uppsala universitet/Institutionen för informationsteknologiSammanfattning : Data processing on streaming data poses computational as well as statistical challenges. Streaming data requires that data processing algorithms are able to process a new data point within micro-seconds. LÄS MER