  1. 1. Fault diagnosis of a variable pole-phase motor

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Claes Henriksson; [2023]
    Nyckelord :Multiphase machine; variable pole-phase machine; fault diagnosis; switch fault; phase fault; harmonic plane decomposition; wound independently controlled stator coil machine; Multifasmaskin; variabel polfasmaskin; feldiagnosticering; brytarfel; fasfel; harmonic plane decomposition; WICSC-maskin;

    Sammanfattning : Wound Independently Controlled Stator Coil (WICSC) machines are a novel type of multiphase machine with the ability to change its pole-phase configuration during operation. This enables improved post-fault control and thus prolonged continuous operation. LÄS MER

  2. 2. Commissioning of a FPGA/DSP unit for Centralized Control of a Variable Phase Pole Multiphase Machine

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Jonas Hansson; [2022]
    Nyckelord :Harmonic Plane Decomposition; Multiphase Electrical Machine; Wound Independently-Controlled Stator Coils; System on a chip; Control Implementation; Hardware Design ; Motorstyrning; Asynkronmotor; Multifasmaskin; Programmering; Systemkrets; Hårdvarukonstruktion;

    Sammanfattning : Multiphase Electrical Machines (MPEMs) with variable phase-pole configurations have recently gained interest as it offers advantages such as a larger operating range and improved fault tolerance compared to more traditional MPEMs. The current state-of-the-art modeling and control method, Vector Space Decomposition (VSD), has the drawback of introducing discontinuities in the model when transitioning from one phase-pole configuration to another. LÄS MER

  3. 3. Evaluation of DC Fault Current in Grid Connected Converters in HVDC Stations

    Master-uppsats, Uppsala universitet/Institutionen för elektroteknik

    Författare :Soham SinhaRoy; [2022]
    Nyckelord :Symmetrical monopole; HVDC LCC and VSC; CTL; MMC; Converter reactor; DC smoothing reactor; DC pole-to-pole fault; Peak factor; SCC; SCR; PSCAD EMTDC;

    Sammanfattning : The main circuit equipment in an HVDC station must be rated for continuous operation as well as for stresses during ground faults and other short circuits. The component impedances are thus selected for proper operation during both continuous operation and short circuit events. LÄS MER

  4. 4. Field Oriented Current Control with Harmonic Injection in a Six-Phase Induction Machine

    Master-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)

    Författare :Xinyue Shan; [2021]
    Nyckelord :Multi-phase machine; asymmetrical six-phase induction machine; harmonic plane decomposition; indirect rotor field oriented control; parameter estimation; Flerfasmaskin; asymmetrisk sexfasinduktionsmaskin; harmonisk plan sönderdelning; indirekt rotorfältorienterad styrning; parameteruppskattning;

    Sammanfattning : As a new type of machine, the multi-phase machine has the advantages ofhigher power rating, higher fault tolerance capability and more degrees offreedom to control compared with the traditional machine. Aiming at runninga multi-phase machine with different phase-pole configurations smoothly,a new method called harmonic plane decomposition is presented. LÄS MER

  5. 5. Evaluation of critical fault scenarios for operation with inherent overload in HVDC stations

    Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Elektricitetslära

    Författare :Lisa Sander; [2018]
    Nyckelord :HVDC; Modular multilevel converter; VSC; transient currents; transient voltages; inherent overload; converter bus fault; pole to pole fault;

    Sammanfattning : The HVDC, High Voltage Direct Current, is important when it comes to upgrading the energy system to a renewable, sustainable and efficient system. This master thesis is investigating what is happening during the most decisive fault cases when the HVDC station is operating with inherent overload. LÄS MER