Sökning: "Leakage current sensing"
Hittade 5 uppsatser innehållade orden Leakage current sensing.
1. Automatic overcurrent and leakage current sensing in multiple channel NMES systems
Kandidat-uppsats, KTH/Skolan för elektroteknik och datavetenskap (EECS)Sammanfattning : This report presents the development, implementation, and testing of a current monitor system that is specifically developed for testing a neuromuscular electrical stimulation system (NMES). The NMES system, developed by KTH and its academic and industrial partners Karolinska institute and Matrix Muscle Support, incorporates advanced features aimed at preventing cardiovascular diseases. LÄS MER
2. Configurable, scalable single-ended sense amplifier with additional auxiliary blocks for low-power two-port memories in advanced FinFET technologies
Master-uppsats, Lunds universitet/Institutionen för elektro- och informationsteknikSammanfattning : System on Chip (SoC) designs contain a variety of Intellectual Property (IP) cores, including digital signal processing blocks, media and graphics processing units, as well as processing core units that employ multiple-port memories to enhance performance and bandwidth. These memories allow parallel read/write operations from the same memory blocks from different ports. LÄS MER
3. Simulation of THz Quantum Cascade Lasers
Master-uppsats, Lunds universitet/Matematisk fysik; Lunds universitet/Fysiska institutionenSammanfattning : Quantum Cascade Lasers (QCLs) have since their invention in 1994 become a crucial source for mid-infrared and THz radiation. Mid-infrared QCLs have achieved room temperature operation while THz QCLs have not. As such, simulations are an important tool in order to achieve a THz QCL operational at room temperature. LÄS MER
4. Distributed Temperature Sensing för kontroll av inläckage i spillvattenledningar
Uppsats för yrkesexamina på avancerad nivå, Uppsala universitet/Institutionen för geovetenskaperSammanfattning : Infiltration and inflow (I/I) are common problems in the foul sewer system. A method to detect I/I that is not commonly used in Sweden is DTS, Distributed Temperature Sensing. DTS is based on continuous measurements of temperature over a predetermined distance in the sewer system. LÄS MER
5. A Differential Measurement Probe with High Common Mode Rejection
Uppsats för yrkesexamina på avancerad nivå, Lunds universitet/Industriell elektroteknik och automationSammanfattning : Measuring signals with high frequency common mode components are typically prone to measurement errors due to low common mode rejection at high frequencies. The purpose of this master thesis is to design a measurement probe that presents sufficient common mode rejection to measure current on high voltage motor drives directly at the switching stage, before filtering. LÄS MER